TN-73 High-precision VU Meter DB Power Discharge Flat Meter Mixer Power Meter
TN-73 High-precision VU Meter DB Power Discharge Flat Meter Mixer Power Meter
Duties & Import Tax
UK orders under £135 incur no additional fees. Otherwise, duties are only included if shown at checkout — your local government may apply customs fees, which your courier will collect directly from you before delivery.
Processed in 1–3 business days
No se pudo cargar la disponibilidad de retiro
UK: Free tracked shipping on every order, no minimum spend.
Everywhere else: Add the product to your cart and use the shipping calculator to see exact methods, rates, and delivery times for your country.
Fast refunds: Once we receive and inspect your return, your refund is processed to your original payment method within 5 business days.
Return postage: Just changed your mind? You'll need to cover the return postage. If the item arrived faulty, we'll cover the cost to get it back to us.
Product Details
High-precision VU Meter DB Power Discharge Flat Meter Mixer Power Meter measures power levels with a movable coil type mechanism. It features a black pointer that swings from left to right.
- Movable part: movable coil type
- Pointer materials: Nickel Silver Strips
- Pointer color: Black
- Direction of pointer swing: From left to right
- Pointer length: 30 +/- 1mm
- Pointer width: 0.45 +/- 0.05mm
- Direction of use: Vertical
- Operating temperature limit: -10°C to +60°C, RH 35% to 85%
- Storage temperature limit: -20°C to +60°C, RH 35% to 85%
- Solder condition: Terminal must be inserted 3mm into tin plate at 230°C for 3.5 seconds
- Solder temperature: 350°C for 3.5 seconds, terminal must be 3mm in contact with solder gun
- Anti-static test: Dry nylon cloth used on transparent cover surface
- Light bulb specification: DC12V 12W
- Standard test conditions: 20°C, 70% humidity
- Pointer sensitivity: 1mA +/- 5%
- Internal impedance: 50 ohm +/- 5%
- Insulation impedance: above 500V DC plus 50M ohm
- Zero position error: +/- 1mm
- Equalization error: +/- 1mm when tilted 90 degrees
- Stick pointer test: Pointer returns to 1/3 of scale
- Friction error range: +/- 1mm
- Braking test: Pointer indicates within one second
- Over load test: Input ten times full scale current
- Vibration test: Shaken 4mm every 1,000 times per minute
- Impact test: Meter dropped from 30cm
- Reliability test: Remains within standard after 100,000 inputs
- Environmental impact test: 50°C, 85% humidity for 100 hours
- Terminal tension test: Terminal must bear 1 kg tension for 60 seconds